Brandywine Miniature GPS Disciplined Oscillator
 
Product Overview
  • Uncompromising performance
  • Low phase noise 10MHz output
  • Internal GPS Tracking Receiver
  • Very small footprint designed for component-level integration
  • Disciplined high-stability OCXO

Description

Brandywine’s miniature GPS Disciplined Oscillator combines the power of our existing disciplined oscillators in a footprint the size of an OCXO. Designed with interoperability in mind, the Miniature GPS Disciplined Oscillator meets military requirements such as MIL-STD-188-164A. The GPSDO supplies a low noise, precision 10 MHz frequency reference signal output. This output is accurate to 1x10-12 when slaved to a GPS source.

The frequency standard is also able to slave to an external 1PPS signal to steer and hold the internal oscillator and clock system precisely in time. Time and frequency information maintains its high accuracy with the internal oscillator even when no satellites can be tracked. A serial data port is provided to report time, date, position, and GPS satellite health and signal strength.

Optional capabilities include automatic interface to an external military GPS receiver such as the Defense Advanced GPS Receiver (DAGR), Standard frequency output is 10 MHZ, but other frequencies are possible.

Specifications & Detail

Inputs

Reference Source:

GPS

Connector MMCX

Signal Type C/A Code

No of Channels 12

Receiver sensitivity -155dBm

Alternative 1PPS input: TTL levels

Power: 12V±5%

3.3V ±5%

Warm up 10W nominal

Steady State 5W nominal

System Specifications

Accuracy

Time accuracy: GPS < 30 ns

1PPS < 30 ns

Holdover <20µs in 24 hrs

Physical

Size: 2.0” x 2.0” x 1.0”

Phase Noise/Short Term Stability (10MHz)

SSB Phase Noise

dBc/Hz

1Hz

-90

10Hz

-120

100Hz

-140

1kHz

-145

10kHz

-150

100kHz

-155

STS ( Allan Variance)+

1sec

<1x10-11

10 sec

<1x10-11

100sec

<1.5x10-11

1000 sec

<1.5x10-11

Outputs

A) 1PPS

TTL levels into 50 ohms

B) 10 MHz

Amplitude: 7dBm Min into 50 ohms

Harmonics: -30dBc

C) GPS lock indicator

Serial Communications

RS232

Environmental Conditions

Temperature

Operating -20 to 60C

Storage -40 to 85C

Altitude: 50,000 ft Non-operating

10,000 ft operating

+After 24 hr operation